针对碳纤维复合材料框架胶接接头的胶接质量问题,提出了使用0.5~10 MHz的宽带窄脉冲探头单侧进行脉冲回波法快速检测。采取试验与理论相结合的方法,采集11种常用接头结构超声波,对其传播特性和检测信号特性进行分析。研究结果表明:试验提出的方法实现了对复合材料框架胶接接头的胶接质量检测,对实际工程检测具有较强的指导意义。
Abstract:In order to solve the problem of bonding quality of carbon fiber composite frame bonding joint,a rapid pulse echo method was proposed using a broad-band narrow-pulse probe of 0.5~10 MHz. 11 kinds of ultrasonic waves for ordinary joint structures were collected by combining experiment with theory,and their propagation characteristics and detection signal characteristics were analyzed. The research results showed that the method proposed in this test achieved the bonding quality detection of composite frame bonding joint,which had strong guiding significance for practical engineering inspection.
[1]贺楣.木塑复合材料胶接接头的无损检测[D].哈尔滨:东北林业大学,2015.
[2]张贺斌.超声检测技术在复合材料构件上的应用研究[D].武汉:武汉理工大学,2011.
[3]马思敏.复合材料T型连接接头力学性能研究[D].哈尔滨:哈尔滨工业大学,2014.
[4]郑祥明,王维斌,史耀武.胶接接头的无损检测[J].无损检测,2003,25(4):184-188;191.
[5]刘清坤.超声无损检测信号消噪及图像评估新算法的研究[D].上海:上海交通大学,2006.
[6]凡丽梅,王从科,郑杰,等.薄壁金属与非金属环形粘接件粘接质量超声检测方法研究[J].测试技术学报,2014,28(6):489-493.
[7]王振清,周松,郭建明,等.混合金属的复合材料加筋板接头设计[C].中国科协年会:复合材料与节能减排研讨会,2013.
[8]袁红梅.粘结结构界面缺陷超声检测技术及其应用研究[D].北京:北京工业大学,2010.
[9]凡丽梅,王从科,赵付宝,等.粘接结构件粘接质量无损检测与信号处理技术研究[J].广东化工,2015,42(21):103-105.
[10]西拉德.超声检测新技术[M].北京:科学出版社,1991.
[11]杨红泽,楚珑晟.玻璃-聚氨酯-玻璃结构界面脱粘缺陷的超声检测[J].无损检测,2017(11):59-63.
[12]薛彩虹,李成良,朱小芹.风电叶片后缘粘接胶理想宽度的模拟[J].玻璃钢/复合材料,2015(4):11-15.
[13]LLOYD E A,BROWN A F.Recent developments in NDTof adhesive-bonded joints[M].London:Applied Science Publishers,1978.
[14]卢伟.木质胶接接头力学性能的研究[D].哈尔滨:东北林业大学,2013.
[15]胡照.探讨超声波探伤原理及方法[J].军民两用技术与产品,2016(20):177.
基本信息:
DOI:10.13416/j.ca.2020.03.007
中图分类号:TG49;TB33
引用信息:
[1]冯君伟,钱云翔,汪丽丽等.复合材料框架胶接接头超声检测研究[J].中国胶粘剂,2020,29(03):27-31+65.DOI:10.13416/j.ca.2020.03.007.
基金信息: